Retrofitting

RB211 CO / SCR Retrofit
Client: Siemens UK
- End User: Centrica
- Scope: design, fabrication, installation and potentially O&M
Operating Conditions – 50% to 100% load
- Mass Flow – 320,400 kg/hr
- Bulk Temperature – 500 °C Design
- NOx Emissions – 140 mg/Nm3
- CO Emissions – 300 mg/Nm3
Stack emission requirements
- NOx Emissions – 35 mg/Nm3
- CO Emissions – 40 to 60 mg/Nm3
- NH3 Slip – 3 mg/Nm3

Centrica Barrow in Furness, UK
BRADEN designed and fabricated the entire system in the UK to minimize risk for this project. BRADEN’s hot catalyst system scope consisted of:
- CFD and Physical Flow Modelling
- CO Reduction System
- Ammonia Vaporization System
- NOx Reduction System
- CEMs Monitoring Probes
- CEMs Analyzer System
- Urea Forwarding Skid
- Site Demolition and Installation
- Commissioning
Download here the PPT-document For SCR (2020 08 06)
Download here the PPT-document Slides and Photos (Past Projects)-2020 08 04
Download here the PPT-document Slides and Photos per group-2020 08 04